Effect of a New Nebulizer on Plasmid DNA Integrity and Gene Transfection |
WANG Hong1,2, SUN Wen-wu2, MA Zhuang2 |
1. Department of Respiratory Medicine, Xijing Hospital, Fouth Military Medical University, Xi’an 710032, China;
2. The Army Center of Respiratory and Allergic Disease Diagnosis and Management, General Hospital of Shenyang Military Region, Shenyang 110016, China |
|
|
Abstract Objective: Explore the effect of a new airway miniaturized nebulizer on the plasmid DNA (pDNA) integrity and animals gene transfection efficiency.Methods: In the first experiment, the effect of the new airway miniaturized nebulizer on pDNA integrity was tested.2ml pDNA(20μg/ml) was put into the sample pool of the new airway miniaturized nebulizer and a clinical commonly used jet nubulizer respectively. Aerosol samples were collected at the 1st min, 3rd min, 5th min from the nozzle of the two nebulizers respectively and investigated with agarose gel electrophoresis.In the second experiment, the effect of gene transfection efficiency of the new airway miniaturized nebulizer on animals was studied.3.3μg PEI/pEGFP (polyethylenimine and plasmid DNA of green fluorescent protein complex formation which contain 3.3μg pEGFP) was aerosolized to rats via the new airway miniaturized nebulizer and a clinical commonly used jet nubulizer respectively.Rats were sacrificed 24h after aerosol treatment. The mRNA was abstracted from the lung of those rats, reverse transcribed into cDNA and determined by real-time PCR. PCR products were also investigated with agarose gel electrophoresis.Result: At the 1st min, 3rd min, 5th min, the proportions of integrity pDNA of the new airway miniaturized nebulizer were (99.6±0.7)%,(100±1.2)%,(99.6±0.7)% respectively, and compared with the control group. The result was no significant difference between the two group(P>0.05, n=3). The effect of the new airway miniaturized nebulizer on plasmid DNA can be neglected.At the 1st min, 3rd min, 5th min, the proportions of integrity pDNA of the clinical commonly used jet nubulizer were (70.3±1.5)%, (49.3±1.5)%,(32.7±0.6)% respectively, and compared with the control group. The results was significantly different between the two group(P<0.05, n=3). The proportion of integrity pDNA of the jet nubulizer was decline graduately accompany with time.The new nebulizer yielded 382.1±101.1 fold higher expression levels than the ordinary jet nebulizer(P<0.01, n=3)Conclution: The new airway miniaturized nebulizer provided an excellent protection on the plasmid DNA, increased the efficiency of gene transfection significantly, and provided a suitable device for aerosol gene therapy.
|
Received: 28 November 2011
Published: 25 March 2012
|
|
|
|
[1] Griesenbach U, Alton E W. Current status and future directions of gene and cell therapy for cystic fibrosis. BioDrugs, 2011, 25(2):77-88.
[2] Zavorotinskaya T, Tomkinson A, Murphy J E. Treatment of experimental asthma by long-term gene therapy directed against IL-4 and IL-13. Mol Ther, 2003, 7(2):155-162.
[3] Christensen C L, Zandi R, Gjetting T, et al. Specifically targeted gene therapy for small-cell lung cancer. Expert Rev Anticancer Ther, 2009, 9(4):437-452.
[4] Lentz Y K, Worden L R, Anchordoquy T J, et al. Effect of jet nebulization on DNA: Identifying the dominant degradation mechanism and mitigation methods. J Aerosol Sci, 2005, 36:973-990.
[5] Danquah M K, Forde G M. Growth medium selection and its economic impact on plasmid DNA production. J Biosci Bioeng, 2007, 104(6):490-497.
[6] Pathak A, Patnaik S, Gupta K C. Recent trends in non-viral vector-mediated gene delivery. Biotechnol J, 2009, 4(11):1559-1572.
[7] 杨慧瑛, 孙文武, 马壮. 机械喷射式雾化机对质粒DNA完整性的影响及保护性研究. 中国生物工程杂志, 2010, 30(10):44-48. Yang H Y, Sun W W, Ma Z. Effect of Jet Nebulizer on Plasmid DNA Integrity and the Research of Protective Methods. China Biotechnology, 2010, 30(10):44-48.
[8] Lesina E, Dames P, Rudolph C. The effect of CpG motifs on gene expression and clearance kinetics of aerosol administered polyethylenimine (PEI)-plasmid DNA complexes in the lung. J Control Release, 2010, 143(2):243-250.
[9] Jiang H L, Hong S H, Kim Y K, et al. Aerosol delivery of spermine-based poly(amino ester)/Akt1 shRNA complexes for lung cancer gene therapy. Int J Pharm, 2011,420 (2):256-265.
[10] Lentz Y K, Anchordoquy T J, Lengsfeld C S. Rationale for the selection of an aerosol delivery system for gene delivery. J Aerosol Med, 2006, 19(3):372-384.
[11] Sun C, Tang T, Uluda H. Molecular dynamics simulations of PEI mediated DNA aggregation. Biomacromolecules, 2011,12(10):3698-3707.
[12] Goyal R, Tripathi S K, Tyagi S, et al. Linear PEI nanoparticles: efficient pDNA/siRNA carriers in vitro and in vivo. Nanomedicine, 2012,8(2):167-175.
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|