综述 |
|
|
|
|
分子即时检测(POCT)技术及其在新发传染病中的应用* |
郭彦彤1,2,刘仲明1,张海燕1,**(),张宝2,**() |
1.中国人民解放军南部战区总医院 广州 510010 2.南方医科大学公共卫生学院 广东省热带病研究重点实验室BSL-3实验室(广东) 广州 510515 |
|
Molecular Diagnostic POCT Technology and Its Application in Emerging Infectious Diseases |
GUO Yan-tong1,2,LIU Zhong-ming1,ZHANG Hai-yan1,**(),ZHANG Bao2,**() |
1. PLA Southern Theater Command General Hospital, Guangzhou 510010, China 2. BSL-3 Laboratory(Guangdong), Guangdong Provincial Key Laboratory of Tropical Disease Research,School of Public Health, Southern Medical University, Guangzhou 510515, China |
引用本文:
郭彦彤,刘仲明,张海燕,张宝. 分子即时检测(POCT)技术及其在新发传染病中的应用*[J]. 中国生物工程杂志, 2022, 42(9): 50-57.
GUO Yan-tong,LIU Zhong-ming,ZHANG Hai-yan,ZHANG Bao. Molecular Diagnostic POCT Technology and Its Application in Emerging Infectious Diseases. China Biotechnology, 2022, 42(9): 50-57.
链接本文:
https://manu60.magtech.com.cn/biotech/CN/10.13523/j.cb.2204057
或
https://manu60.magtech.com.cn/biotech/CN/Y2022/V42/I9/50
|
[1] |
Zarei M. Advances in point-of-care technologies for molecular diagnostics. Biosensors and Bioelectronics, 2017, 98: 494-506.
doi: S0956-5663(17)30473-6
pmid: 28728010
|
[2] |
Wang Y, Yu L, Kong X, et al. Application of nanodiagnostics in point-of-care tests for infectious diseases. Int J Nanomedicine, 2017, 12: 4789-4803.
doi: 10.2147/IJN.S137338
|
[3] |
Moerner W E, Shechtman Y, Wang Q. Single-molecule spectroscopy and imaging over the decades. Faraday Discussions, 2015, 184: 9-36.
doi: 10.1039/c5fd00149h
pmid: 26616210
|
[4] |
Heo J H, Cho H H, Lee J W, et al. Achromatic-chromatic colorimetric sensors for on-off type detection of analytes. The Analyst, 2014, 139(24): 6486-6493.
doi: 10.1039/C4AN01645A
|
[5] |
Bahadır E B, Sezgintürk M K. Electrochemical biosensors for hormone analyses. Biosensors and Bioelectronics, 2015, 68: 62-71.
doi: S0956-5663(14)01008-2
pmid: 25558874
|
[6] |
Liu J J, Geng Z X, Fan Z Y, et al. Point-of-care testing based on smartphone: the current state-of-the-art (2017-2018). Biosensors and Bioelectronics, 2019, 132: 17-37.
doi: S0956-5663(19)30132-0
pmid: 30851493
|
[7] |
Geng Z X, Zhang X, Fan Z Y, et al. Recent progress in optical biosensors based on smartphone platforms. Sensors (Basel, Switzerland), 2017, 17(11): 2449.
doi: 10.3390/s17112449
|
[8] |
Hutchison J R, Erikson R L, Sheen A M, et al. Reagent-free and portable detection of Bacillus anthracis spores using a microfluidic incubator and smartphone microscope. The Analyst, 2015, 140(18): 6269-6276.
doi: 10.1039/C5AN01304F
|
[9] |
Nguyen H Q, Nguyen V D, van Nguyen H, et al. Quantification of colorimetric isothermal amplification on the smartphone and its open-source app for point-of-care pathogen detection. Scientific Reports, 2020, 10: 15123.
doi: 10.1038/s41598-020-72095-3
pmid: 32934342
|
[10] |
Oh S J, Park B H, Choi G, et al. Fully automated and colorimetric foodborne pathogen detection on an integrated centrifugal microfluidic device. Lab on a Chip, 2016, 16(10): 1917-1926.
doi: 10.1039/c6lc00326e
pmid: 27112702
|
[11] |
Nguyen H V, Nguyen V D, Lee E Y, et al. Point-of-care genetic analysis for multiplex pathogenic bacteria on a fully integrated centrifugal microdevice with a large-volume sample. Biosensors and Bioelectronics, 2019, 136: 132-139.
doi: S0956-5663(19)30326-4
pmid: 31078871
|
[12] |
Xu H, Xia A Y, Wang D D, et al. An ultraportable and versatile point-of-care DNA testing platform. Science Advances, 2020, 6(17): eaaz7445.
doi: 10.1126/sciadv.aaz7445
|
[13] |
Pollock N R, Rolland J P, Kumar S, et al. A paper-based multiplexed transaminase test for low-cost, point-of-care liver function testing. Science Translational Medicine, 2012, 4(152): 152ra129.
|
[14] |
Mandal N, Dutta S, Gupta A, et al. Paper-based sensors for point-of-care kidney function monitoring. IEEE Sensors Journal, 2020, 20(17): 9644-9651.
doi: 10.1109/JSEN.2020.2990231
|
[15] |
Chan C W, Parker K, Tesic V, et al. Analytical and clinical evaluation of the automated elecsys anti-SARS-CoV-2 antibody assay on the Roche cobas e602 analyzer. American Journal of Clinical Pathology, 2020, 154(5): 620-626.
doi: 10.1093/ajcp/aqaa155
pmid: 32814955
|
[16] |
Wang F F, Fu C P, Huang C, et al. Paper-based closed Au-Bipolar electrode electrochemiluminescence sensing platform for the detection of miRNA-155. Biosensors & Bioelectronics, 2020, 150: 111917.
doi: 10.1016/j.bios.2019.111917
|
[17] |
Dincer C, Bruch R, Kling A, et al. Multiplexed point-of-care testing - xPOCT. Trends in Biotechnology, 2017, 35(8): 728-742.
doi: S0167-7799(17)30062-8
pmid: 28456344
|
[18] |
Kumar S, Rai P, Sharma J G, et al. PEDOT: PSS/PVA-nanofibers-decorated conducting paper for cancer diagnostics. Advanced Materials Technologies, 2016, 1(4): 1600056.
doi: 10.1002/admt.201600056
|
[19] |
Tur-García E L, Davis F, Collyer S D, et al. Novel flexible enzyme laminate-based sensor for analysis of lactate in sweat. Sensors and Actuators B: Chemical, 2017, 242: 502-510.
doi: 10.1016/j.snb.2016.11.040
|
[20] |
Dossi N, Toniolo R, Impellizzieri F, et al. A paper-based platform with a pencil-drawn dual amperometric detector for the rapid quantification of ortho-diphenols in extravirgin olive oil. Analytica Chimica Acta, 2017, 950: 41-48.
doi: S0003-2670(16)31322-8
pmid: 27916128
|
[21] |
Nguyen P Q, Soenksen L R, Donghia N M, et al. Wearable materials with embedded synthetic biology sensors for biomolecule detection. Nature Biotechnology, 2021, 39(11): 1366-1374.
doi: 10.1038/s41587-021-00950-3
pmid: 34183860
|
[22] |
Zhu H L, Fohlerová Z, Pekárek J, et al. Recent advances in lab-on-a-chip technologies for viral diagnosis. Biosensors and Bioelectronics, 2020, 153: 112041.
doi: 10.1016/j.bios.2020.112041
|
[23] |
Sinha M, Mack H, Coleman T P, et al. A high-resolution digital DNA melting platform for robust sequence profiling and enhanced genotype discrimination. SLAS Technology, 2018, 23(6): 580-591.
doi: 10.1177/2472630318769846
pmid: 29652558
|
[24] |
Qin P W, Park M, Alfson K J, et al. Rapid and fully microfluidic Ebola virus detection with CRISPR-Cas13a. ACS Sensors, 2019, 4(4): 1048-1054.
doi: 10.1021/acssensors.9b00239
pmid: 30860365
|
[25] |
Srisomwat C, Teengam P, Chuaypen N, et al. Pop-up paper electrochemical device for label-free hepatitis B virus DNA detection. Sensors and Actuators B: Chemical, 2020, 316: 128077.
doi: 10.1016/j.snb.2020.128077
|
[26] |
Trick A Y, Ngo H T, Nambiar A H, et al. Filtration-assisted magnetofluidic cartridge platform for HIV RNA detection from blood. Lab on a Chip, 2022, 22(5): 945-953.
doi: 10.1039/d1lc00820j
pmid: 35088790
|
[27] |
Shan C, Xie X P, Barrett A D T, et al. Zika virus: diagnosis, therapeutics, and vaccine. ACS Infectious Diseases, 2016, 2(3): 170-172.
doi: 10.1021/acsinfecdis.6b00030
pmid: 27623030
|
[28] |
Kost G J. Molecular and point-of-care diagnostics for Ebola and new threats: national POCT policy and guidelines will stop epidemics. Expert Review of Molecular Diagnostics, 2018, 18(7): 657-673.
doi: 10.1080/14737159.2018.1491793
pmid: 29933717
|
[29] |
Pang J X, Chia P Y, Lye D C, et al. Progress and challenges towards point-of-care diagnostic development for dengue. Journal of Clinical Microbiology, 2017, 55(12): 3339-3349.
doi: 10.1128/JCM.00707-17
pmid: 28904181
|
[30] |
Wang C, Liu M, Wang Z F, et al. Point-of-care diagnostics for infectious diseases: from methods to devices. Nano Today, 2021, 37: 101092.
doi: 10.1016/j.nantod.2021.101092
|
[31] |
Tsang H F, Leung W M S, Chan L W C, et al. Performance comparison of the Cobas® Liat® and Cepheid® GeneXpert® systems on SARS-CoV-2 detection in nasopharyngeal swab and posterior oropharyngeal saliva. Expert Review of Molecular Diagnostics, 2021, 21(5): 515-518.
doi: 10.1080/14737159.2021.1919513
|
[32] |
Cassidy H, van Genne M, Lizarazo-Forero E, et al. Evaluation of the QIAstat-Dx RP2.0 and the BioFire FilmArray RP2.1 for the rapid detection of respiratory pathogens including SARS-CoV-2. Frontiers in Microbiology, 2022, 13: 854209.
doi: 10.3389/fmicb.2022.854209
|
[33] |
何维芝, 许彬, 蒋立. 不同提取及扩增方法检测新型冠状病毒核酸的性能比较分析. 华南预防医学, 2022, 48(1): 135-138.
|
|
He W Z, Xu B, Jiang L. Comparative analysis of the performance of different extraction and amplification methods for the detection of nucleic acids of SARS-CoV-2. South China Journal of Preventive Medicine, 2022, 48(1): 135-138.
|
[34] |
Hansen G, Marino J, Wang Z X, et al. Clinical performance of the point-of-care cobas liat for detection of SARS-CoV-2 in 20 minutes: a multicenter study. Journal of Clinical Microbiology, 2021, 59(2): e02811-e02820.
|
[35] |
Lucena Baeza L, Pfennigwerth N, Hamprecht A. Rapid and easy detection of carbapenemases in enterobacterales in the routine laboratory using the new GenePOC carba/revogene carba C assay. Journal of Clinical Microbiology, 2019, 57(9): e00597-e00519.
|
[36] |
Ramachandran A, Noble J, Deucher A, et al. Performance of Abbott ID-Now rapid nucleic amplification test for laboratory identification of COVID-19 in asymptomatic emergency department patients. Journal of the American College of Emergency Physicians Open, 2021, 2(6): e12592.
|
[37] |
Kim H N, Jang W S, Nam J, et al. Performance evaluation of Alere i influenza A&B in detecting influenza viruses A and B. Annals of Clinical and Laboratory Science, 2021, 51(1): 106-111.
|
[38] |
Ganguli A, Mostafa A, Berger J, et al. Rapid isothermal amplification and portable detection system for SARS-CoV-2. Proceedings of the National Academy of Sciences of the United States of America, 2020, 117(37): 22727-22735.
|
[39] |
Zhao H, Liu F, Xie W, et al. Ultrasensitive supersandwich-type electrochemical sensor for SARS-CoV-2 from the infected COVID-19 patients using a smartphone. Sensors and Actuators B: Chemical, 2021, 327: 128899.
doi: 10.1016/j.snb.2020.128899
|
[40] |
Chan K, Weaver S C, Wong P Y, et al. Rapid, affordable and portable medium-throughput molecular device for Zika virus. Scientific Reports, 2016, 6: 38223.
doi: 10.1038/srep38223
pmid: 27934884
|
[41] |
Chen P, Chen C, Su H Y, et al. Integrated and finger-actuated microfluidic chip for point-of-care testing of multiple pathogens. Talanta, 2021, 224: 121844.
doi: 10.1016/j.talanta.2020.121844
|
[42] |
Sun F, Ganguli A, Nguyen J, et al. Smartphone-based multiplex 30-minute nucleic acid test of live virus from nasal swab extract. Lab on a Chip, 2020, 20(9): 1621-1627.
doi: 10.1039/d0lc00304b
pmid: 32334422
|
[43] |
Gong Y, Zheng Y M, Jin B R, et al. A portable and universal upconversion nanoparticle-based lateral flow assay platform for point-of-care testing. Talanta, 2019, 201: 126-133.
doi: S0039-9140(19)30373-X
pmid: 31122402
|
[44] |
Park Y M, Lim S Y, Jeong S W, et al. Flexible nanopillar-based electrochemical sensors for genetic detection of foodborne pathogens. Nano Convergence, 2018, 5: 15.
doi: 10.1186/s40580-018-0147-0
pmid: 29904621
|
[45] |
Azmi I, Faizan M I, Kumar R, et al. A saliva-based RNA extraction-free workflow integrated with Cas13a for SARS-CoV-2 detection. Frontiers in Cellular and Infection Microbiology, 2021, 11: 632646.
doi: 10.3389/fcimb.2021.632646
|
[46] |
Alafeef M, Moitra P, Dighe K, et al. RNA-extraction-free nano-amplified colorimetric test for point-of-care clinical diagnosis of COVID-19. Nature Protocols, 2021, 16(6): 3141-3162.
doi: 10.1038/s41596-021-00546-w
pmid: 33931780
|
[47] |
Mao R, Qi L F, Wang Z, et al. Helix loop-mediated isothermal amplification of nucleic acids. RSC Advances, 2018, 8(34): 19098-19102.
doi: 10.1039/C8RA01201F
|
[48] |
Go Y Y, Rajapakse R P V J, Kularatne S A M, et al. A pan-dengue virus reverse transcription-insulated isothermal PCR assay intended for point-of-need diagnosis of dengue virus infection by use of the POCKIT nucleic acid analyzer. Journal of Clinical Microbiology, 2016, 54(6): 1528-1535.
doi: 10.1128/JCM.00225-16
pmid: 27030492
|
[49] |
Yang M J, Ke Y H, Wang X S, et al. Development and evaluation of a rapid and sensitive EBOV-RPA test for rapid diagnosis of Ebola virus disease. Scientific Reports, 2016, 6: 26943.
doi: 10.1038/srep26943
pmid: 27246147
|
[50] |
Priye A, Wong S, Bi Y P, et al. Lab-on-a-drone: toward pinpoint deployment of smartphone-enabled nucleic acid-based diagnostics for mobile health care. Analytical Chemistry, 2016, 88(9): 4651-4660.
doi: 10.1021/acs.analchem.5b04153
pmid: 26898247
|
[51] |
Guo M Z, Gao B B, He B F. Paper and pseudo-paper based flexible membrane devices. Chinese Science Bulletin, 2020, 65(23): 2454-2468.
|
[52] |
Chiang C K, Kurniawan A, Kao C Y, et al. Single step and mask-free 3D wax printing of microfluidic paper-based analytical devices for glucose and nitrite assays. Talanta, 2019, 194: 837-845.
doi: 10.1016/j.talanta.2018.10.104
|
[53] |
Augustine R, Hasan A, Das S, et al. Loop-mediated isothermal amplification (LAMP): a rapid, sensitive, specific, and cost-effective point-of-care test for coronaviruses in the context of COVID-19 pandemic. Biology, 2020, 9(8): 182.
doi: 10.3390/biology9080182
|
[54] |
Zhang J Q, Nfon C, Tsai C F, et al. Development and evaluation of a real-time RT-PCR and a field-deployable RT-insulated isothermal PCR for the detection of Seneca Valley virus. BMC Veterinary Research, 2019, 15(1): 168.
doi: 10.1186/s12917-019-1927-4
pmid: 31126297
|
[55] |
Miao G J, Zhang L L, Zhang J, et al. Free convective PCR: from principle study to commercial applications-A critical review. Analytica Chimica Acta, 2020, 1108: 177-197.
doi: S0003-2670(20)30138-0
pmid: 32222239
|
[56] |
Luo K, Kim H Y, Oh M H, et al. Paper-based lateral flow strip assay for the detection of foodborne pathogens: principles, applications, technological challenges and opportunities. Critical Reviews in Food Science and Nutrition, 2020, 60(1): 157-170.
doi: 10.1080/10408398.2018.1516623
pmid: 30311773
|
[57] |
Morbioli G G, Mazzu-Nascimento T, Stockton A M, et al. Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (μPADs) - A review. Analytica Chimica Acta, 2017, 970: 1-22.
doi: S0003-2670(17)30348-3
pmid: 28433054
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|