Please wait a minute...

中国生物工程杂志

China Biotechnology
China Biotechnology  2009, Vol. 29 Issue (07): 87-93    DOI:
    
Analysis of mass isotopomer distributions of proteingenic amino acids Used GC-MS during 13CMFA
Download: HTML   PDF(770KB) HTML
Export: BibTeX | EndNote (RIS)      

Abstract  

Abstract 13C metabolic flux analysis (13CMFA) have been the research hotspots of metabolic engineering internationally due to its accuracy and applicability.It is vital that the measurement of 13C labelling pattern of proteinogenic amino acids for 13C metabolic flux analysis.To acquire 13C-labelling proteinogenic amino acids,Pseudomonas denitrifican which products Vitamin B12 was firstly fed with mimimal culture medium contained 20% U-13C and 80% natural glucose,after the culture reached a steady state, then about 20 mg biomass was hydrolyzed by 1 ml of 6 mol/L hydrochloric acid for 24h at 110℃.Then amino acids was separated,concentrated, evaporated in a vacuum, and derivatized with MBDSTFA, TBDMS-derivatized amino acids can be observed by GC-MS last we get 13C labelling pattern of fifteen aminio acids through mass spectrum.The experimental methods and sample preparation offers referential value for the development of 13C metabolic flux analysis in our courtry.



Key words13CMFA;GC-MS;amino derivatization;13C labeling pattern     
Received: 10 February 2009      Published: 28 July 2009
ZTFLH:  中图分类号Q519  
Cite this article:

WANG Jian, WANG Ze-Jian, HUANG Meng-Zhi, JIAN Jiang-Chao, CHU Ju, ZHANG Si-Liang. Analysis of mass isotopomer distributions of proteingenic amino acids Used GC-MS during 13CMFA. China Biotechnology, 2009, 29(07): 87-93.

URL:

https://manu60.magtech.com.cn/biotech/     OR     https://manu60.magtech.com.cn/biotech/Y2009/V29/I07/87

[1] Wiechert W.13C metabolic flux analysis. Metab Eng,2001,3(3):195~206 [2] Wiechert W, Mollney M, Petersen S, et al.A universal framework for 13C metabolic fux analysis. Metab Eng,2001,3(3):265~283 [3] Christensen B, Gombert A K, Nielsen J.Analysis of flux estimates based on 13C-labelling experiments. Eur J Biochem,2002,269(11):2795~2800 [4] 李晓静,陈涛,陈洵,等.13C代谢通量分析.化工进展, 2006,18(7):995~1001 Li X J,Chen T,Chen X,et al.Progress In Chemistry, 2006,18(7):995~1001 [5] Dauner M, Sauer U .GC-MS analysis of amino acids rapidly provides rich information for isotopomer balancing. Biotechnol Prog,2000,16(16):642~649 [6] Zhao J, Shimizu K. Metabolic flux analysis of Escherichia coli K12 grown on 13C-labeled acetate and glucose using GC-MS and powerful flux calculation method. J Biotechnol,2003, 101(2):101~117 [7] Cannizzaro C, Christensen B, Nielsen J, et al. Metabolic network analysis on Phaffia rhodozyma yeast using 13C-labeled glucose and gas chromatography-mass spectrometry. Metab Eng,2004, 6(4):340~351 [8] Segura J,Ventura R, Jurado C.Derivatization procedures for gas chromatgraphic–mass spectrometric determination of xenobiotics in biological samples, with special attention to drugs of abuse and doping agents. J Chromatogr B Biomed Sci Appl,1998,713(1):61~90 [9] Halket J M, Zaikin V G.Derivatization in mass spectrometry-1 Silylation Eur J Mass Spectrom,2003,9(1):1~21 [10] Christensen B, Nielsen J.Isotopomer analysis using GC-MS. Metab Eng,1999,1:282~290 [11] Rosman K J R, Taylor P D P. Isotopic composition of the elements.Pure Appl Chern,1998,70:217~231 [12] Corso T N, Brenna J T. High-precision position-specific isotope analysis. Proc Natl Acad Sci USA,1997, 94(4):1049~1053
No related articles found!